31
Message
%1
●P009 Memory card read error (err)
PCMCIA ATA Card (Slot%1 sector %2): Read Sector Error
Slot (A | B)
%2
Sector number
Explanation
A sector read error occurred. The card may be damaged.
Response
Check the memory card and, if necessary, reformat the card. If there is a physical
fault on the card, replace the card.
Message
%1
●P010 Memory card write error (err)
PCMCIA ATA Card (Slot%1 sector %2): Write Sector Error
Slot (A | B)
%2
Sector number
Explanation
A sector write error occurred. The card may be damaged.
Response
Check the memory card and, if necessary, reformat the card. If there is a physical
fault on the card, replace the card.
Message
Explanation
●S001 Ethernet interface initialization failed (crit)
eci: netif can't up
Network interface initialization failed.
Response
If rebooting does not solve the problem, there is a malfunction. Contact an authorized
Canon service representative.
Message
Explanation
●S002 Ethernet route registration failure (err)
eci: net route can't add
An attempt to register a route for a local Ethernet segment failed.
Response
Correct the Ethernet settings and reboot.
Message
Explanation
●S003 Ethernet default route registration failed (err)
eci: default route can't add
Registration of the default Ethernet route failed.
Response
Correct the Ethernet settings and reboot.