Explanation
Response
A007 View restriction setting error (warning)
inconsistent view restriction for camera[%1]
The view restriction settings are corrupted. The camera control functions on the
affected camera cannot be used.
Restore the factory default settings or reset the view restrictions.
%1
Camera number (1-4)
Message
Explanation
Response
A008 Compatibility error in the view restrictions settings (warning)
unacceptable view restriction for camera[%1]
Even in the telephoto field of view, the view restriction settings cannot be satisfied in the horizontal or
vertical direction. When this occurs, the zoom setting is fixed at the telephoto field of view, and camera
head control is prohibited in directions that do not satisfy the permitted field of view restrictions.
Set appropriate values for the view restrictions.
%1
Camera number (1-4)
Classification
crit
err
Fault Severity
Critical fault at the software level (stops task operation)
Fault involving a malfunction (operation interrupted)
Level
Error
Error
warning
notice
info
Fault not involving malfunction
Fault outside the system
Information on correct operation
Warning
Warning
Information
Message
Explanation
Response
A005 Camera control channel assignment error (warning)
conflicting channel assignment for %1:%2
The same camera control port (a combination of camera control port and cascade
number) is assigned to multiple video input channels. Or, the specified cascade
numbers are not in sequence. The settings may be corrupted.
Correct the settings or restore the factory default settings.
%1
%2
Camera control port (CC1 | CC2)
Cascade number (1-4)
Message
Explanation
Response
A006 Camera control system initialization failure (err)
cannot open camera control port %1
The camera control port cannot be opened.
If rebooting does not solve this problem, there is a malfunction. Contact an
authorized Canon service representative.
%1
Camera control port (CC1 | CC2)
Log Messages
Application-related Log Messages
The Syslog log messages are classified into the following 5 categories. Classification details are dealt with
in the UNIX syslog the levels are explained on page 56 of the VB150 User's Manual.
* The syslog facility is local7.