List of Log Messages
8-15
8
Appendix
S412 Timer service initialization error [crit]
S413 Timer service runtime error [crit]
S501 Fan stop detected [alert] (VB-M600VE)
S502 Temperature fuse disconnect detected [alert]
(VB-M600VE)
Description timer initialization error [%1] [%2] (S412)
%1 Error number
%2 Cause of error
Meaning An error occurred in the initialization of the
timer service.
Countermeasure
If the problem persists after rebooting, the
camera is faulty. Arrange for servicing.
Description timer working error [%1] (S413)
%1 Error number
Meaning An error occurred while the timer service
was running.
Countermeasure
If the problem persists after rebooting, the
camera is faulty. Arrange for servicing.
Description FAN rotation speed is less than 150rpm.
(S501)
Meaning The camera's internal fan has stopped or
RPM has dropped significantly.
Countermeasure
Camera needs to be serviced.
Description Heater unit error. Fuse is cut off. (S502)
Meaning The temperature fuse on the heater
substrate was disconnected.
Countermeasure
Camera needs to be serviced.
Komentáře k této Příručce